Fire emergency planning guide

Emergency evacuation plan guide

An emergency plan turns the risk assessment and building design into clear, workable actions for a fire. It must reflect the actual people, staffing, layout and evacuation strategy—not a generic notice.

Reviewed: 22 July 2026Guidance: EnglandReading time: approximately 8 minutes

Building-specific choice

Simultaneous, phased, progressive and stay-put strategies

The correct strategy is determined by the building design, occupants and risk assessment. It should not be changed casually because alarm operation, compartmentation, staffing and escape capacity may have been designed around it.

01

Simultaneous evacuation

Everyone responds and leaves together; common in workplaces and many public premises.

02

Phased evacuation

Selected floors or zones evacuate in a controlled sequence, often in suitably designed high-rise buildings.

03

Progressive horizontal evacuation

People move to a fire-resisting compartment on the same level before further movement; used where immediate vertical escape is difficult, such as some care settings.

04

Stay put

In suitable purpose-built blocks, residents not affected by fire may remain in their flats while the fire service deals with the incident; anyone affected should leave if able.

Inclusive evacuation

Plan for vulnerable people, visitors and changing occupancy

The plan must consider people who may need help because of mobility, sensory or cognitive needs, age, temporary injury or unfamiliarity. Do not rely on the fire and rescue service to provide routine evacuation assistance.

Arrangements may include personal or generic plans, named assistance, refuges with communication, evacuation equipment, accessible information and suitable staffing. From 6 April 2026, specific Residential PEEPs duties apply to defined residential buildings and residents.

After leaving

Assembly points and accountability

Choose an accessible location far enough from the building and hazards, away from fire-service access and not requiring people to cross unsafe traffic routes. Large or complex sites may need several points and an alternative location.

Accountability methods should fit the premises: staff lists, visitor systems, resident information or area sweeps may contribute, but no one should re-enter to search. Missing-person information should be passed promptly to the fire service.

  • Clearly identify primary and alternative assembly points
  • Include staff, visitors, contractors and out-of-hours occupants
  • Assign who receives roll-call or sweep information
  • Prevent crowding at entrances and appliance routes
  • State who may authorise re-entry

Make it workable

Communicate, practise and review the plan

Provide relevant information on induction and when arrangements change. Train people with specific roles, coordinate with other occupiers and use drills or exercises to test assumptions without creating unsafe surprise.

Review after drills, incidents, false alarms, building works, staffing changes, changes to people needing assistance or failures of a key system. Record what happened and close corrective actions.

  • Issue concise instructions at points of need
  • Make alternative arrangements for nights, weekends and lone working
  • Test communications and assistance, not only travel time
  • Record lessons, owners and completion dates
  • Keep the FRA, fire strategy and emergency plan aligned

Apply the guidance

Connect the requirement to your premises

Use a property-specific guide for the risks and management questions relevant to your building, or explore the local London and Surrey assessment pages.

01Property guides02Location guidance03Assessment quote

Frequently asked questions

Emergency evacuation plan guide FAQs

Does every business need a written fire evacuation plan?

The responsible person must establish appropriate procedures and record fire-safety arrangements. Since October 2023, fire-safety arrangements must be recorded in all cases, so the evacuation arrangements should be documented proportionately.

What is the difference between stay put and phased evacuation?

Stay put normally relies on residential compartmentation so unaffected residents may remain in their flats. Phased evacuation moves selected floors or zones in a planned sequence using building systems and managed capacity.

Must an assembly point be outside?

The objective is a place of relative or ultimate safety appropriate to the building and scenario. For most ordinary premises this is a safe outdoor location, but complex sites may use staged arrangements designed into the strategy.

Who is responsible for helping a disabled person evacuate?

The responsible person must make suitable arrangements and cannot plan to rely on fire-service rescue as the normal solution. The exact assistance and people involved should be agreed, resourced and practised.

London and Surrey support

Ask about a professional assessment

Tell us what premises you are responsible for and what prompted your enquiry. Your details can be reviewed and passed to an assessor serving your area.

  • No obligation to book
  • Telephone number required
  • Use the details box for risks, changes or deadlines

Submitting this form does not confirm an appointment, compliance outcome or fixed price.

Sources and limitations

Guidance reviewed 22 July 2026

This page provides general information for England. It is not legal advice or a building-specific assessment. Fire Safety Services is independent and is not affiliated with the Government, enforcing authorities, BAFE, NFRAR or IFSM.

Related assessment guides

Continue reading