Preventive measures guide

Fire prevention and control in the workplace

Fire prevention starts by removing avoidable ignition and fuel hazards, then controlling what remains. It should be designed around the real work, occupancy and building—not a generic list of rules.

Reviewed: 9 September 2026Guidance: EnglandReading time: approximately 8 minutes

Prevention principles

Reduce risk at source before relying on response

The Fire Safety Order’s prevention principles include avoiding risks, evaluating risks that cannot be avoided, combating risks at source, adapting to technical progress and replacing dangerous processes or substances with less dangerous alternatives where appropriate.

Detection, escape and firefighting equipment remain important, but they do not justify preventable ignition or unmanaged fuel. Start with elimination and reduction, then add engineered and management controls.

01

Eliminate

Remove unnecessary ignition sources, combustible storage or hazardous processes.

02

Substitute

Use a less hazardous substance, process, appliance or storage method where practicable.

03

Separate

Keep heat, sparks and flames away from fuel and protect high-risk areas.

04

Engineer

Use suitable installation, ventilation, shut-off, containment and automatic protection.

05

Manage

Apply training, permits, supervision, inspection and emergency arrangements.

Common causes

Control ignition, fuel and oxygen

The FRA should identify how a fire could start, what could burn and whether oxidising materials or oxygen enrichment could intensify it. The combinations matter: an ordinary appliance can become a serious hazard beside combustible storage or where maintenance is poor.

Hazard groupExamples of controls
Electrical and chargingSuitable equipment, fixed-installation maintenance, defect reporting, safe charging areas and no overloaded sockets
Heating and cookingClear separation, extraction cleaning, shut-off, supervision and safe closing procedures
Smoking and deliberate fire-settingControlled smoking arrangements, secure waste, lighting, access control and external housekeeping
Hot work and contractorsAuthorisation, area preparation, isolation, extinguishing provision and post-work fire watch
Flammable or oxidising substancesMinimum quantities, compatible storage, ventilation, spill control and ignition exclusion
Combustible waste and storageFrequent removal, safe stacking, protected routes and separation from heat or external walls

Changing risks

Manage batteries and electrical mobility devices as a system

Lithium-ion batteries can fail after damage, modification, incompatible charging, overheating or manufacturing defects. Controls should cover purchase, permitted devices, charging locations, inspection, damaged-battery quarantine, storage and emergency response.

Do not charge e-bikes, e-scooters or other large batteries on escape routes. Consider whether charging can be moved away from sleeping areas and combustible storage, and use manufacturer-approved equipment. Escalate swelling, unusual heat, noise, odour or damage.

  • Define which devices and chargers are permitted
  • Provide suitable charging locations away from escape routes
  • Prevent unattended charging where the assessment identifies risk
  • Remove damaged or recalled products from use
  • Plan safe isolation and emergency response
  • Review insurer, housing and official product-safety information

Daily operation

Build prevention into opening, occupation and closing routines

Many controls depend on behaviour at predictable points: opening the building, starting hazardous processes, contractor arrival, changes of shift and closing. Use concise checks that match the premises rather than one oversized generic form.

Temporary change deserves particular attention. Events, maintenance, deliveries, blocked areas and seasonal displays can alter escape and fuel load for a short period but create immediate risk.

  • Confirm routes and exits before admitting occupants
  • Check high-risk equipment and extraction before use
  • Control keys, access and security without obstructing escape
  • Brief contractors and supervise high-risk work
  • Remove waste and isolate equipment at close
  • Record exceptions, faults and temporary controls

Check effectiveness

Use incidents, defects and near misses to improve controls

Repeated overheating, false alarms, scorch marks, tripped circuits, smoking breaches or hot-work problems are warning data. Investigate patterns before they become a fire.

Review the FRA after a fire, near miss or significant change and where there is reason to suspect it is no longer valid. Prevention actions should have owners and deadlines, with evidence that the risk—not just the paperwork—was addressed.

01

Observe

Use inspections, conversations and records to identify weak controls.

02

Investigate

Find underlying causes rather than repeatedly correcting symptoms.

03

Improve

Change equipment, layout, process, supervision or training.

04

Verify

Check the control is sustained and revise the FRA where necessary.

Related guidance and support

Continue with premises and local guidance

Choose the closest property guide, then use the relevant London or Surrey route when you are ready to compare local assessment support.

01Property guides02London FRA guide03Surrey FRA guide04Assessment quote

Frequently asked questions

Fire prevention and control in the workplace FAQs

What is the difference between fire prevention and fire protection?

Prevention reduces the likelihood of fire starting or growing. Protection limits consequences through measures such as detection, alarms, compartmentation, escape, emergency lighting and firefighting equipment. Effective fire safety needs both.

What are the main workplace fire hazards?

Common groups include electrical faults, heating and cooking, smoking, hot work, flammable substances, batteries, combustible storage, waste and deliberate fire-setting. The relevant combination depends on the premises.

Who should manage hot work?

The organisation controlling the premises and work should use competent people and a proportionate authorisation process covering preparation, isolation, firefighting provision, supervision and post-work monitoring.

Can fire extinguishers compensate for poor prevention?

No. Extinguishers are a secondary measure and only suitable where users can act without putting themselves at risk. Avoidable ignition and fuel hazards should be removed or reduced first.

When should preventive controls trigger an FRA review?

Review when there is reason to suspect the FRA is no longer valid or after significant change, including new processes, substances, layouts, occupancy, incidents, repeated defects or loss of protection.

London and Surrey support

Ask about a professional assessment

Tell us what premises you are responsible for and what prompted your enquiry. Your details can be reviewed and passed to an assessor serving your area.

  • No obligation to book
  • Telephone number required
  • Use the details box for risks, changes or deadlines

Submitting this form does not confirm an appointment, compliance outcome or fixed price.

Sources and limitations

Guidance reviewed 9 September 2026

This page provides general information for England. It is not legal advice or a building-specific assessment. Fire Safety Services is independent and is not affiliated with the Government, enforcing authorities, BAFE, NFRAR or IFSM.