Door inventory
Identify and uniquely reference doors by building, floor, location, use and type.
Inspection, records and remedial priorities
Arrange a fire door survey or inspection, understand the checks that apply to your building and request a quote across London and Surrey.
Service overview
A fire door is a complete life-safety assembly: door leaf, frame, glazing, seals, hinges, closer, latch, ironmongery and the surrounding construction must work together. A labelled leaf alone does not prove that the installed doorset will perform as intended.
Inspection should consider the fire strategy, certification or evidence available, door location and required performance. Visual checks can identify many defects, but intrusive investigation or specialist evidence may be needed when construction, installation or fire resistance cannot be established.
Start with the fire risk assessment. It should identify the precautions needed for the actual premises and explain how this service fits the emergency plan and wider fire-safety arrangements. Read the fire risk assessment guide.
Scope of work
A quotation should state exactly which parts of the work are included and who is responsible for design decisions, access, certification and any remedial work.
Identify and uniquely reference doors by building, floor, location, use and type.
Check the leaf, frame, gaps, seals, hinges, closer, latch, glazing, ironmongery and signs of alteration or damage.
Confirm the door opens appropriately, self-closes reliably from relevant positions and closes into the frame without obstruction.
Consider labels, plugs, certificates, schedules, drawings and other evidence supporting the doorset specification.
Record photographs and defects, distinguish urgent safety issues from planned works and make clear recommendations.
Reinspect completed repairs or replacement work where confirmation is included in the agreed scope.
Building-specific requirements
The examples below are a guide, not a specification. The appropriate solution must follow the premises risk, use, relevant standards and any existing fire strategy.
Protect common escape routes and form part of the clarified Fire Safety Order scope for blocks containing two or more domestic premises.
Stair, corridor, lobby, riser, plant-room and cross-corridor doors support compartmentation and protected routes.
Doors protecting escape routes, hazardous rooms, compartments and fire-resisting construction need suitable maintenance.
Doors exposed to frequent traffic, damage, access-control work or new ironmongery often justify closer attention.
Law and recognised guidance
British Standards are codes of practice rather than legislation in themselves. They can nevertheless provide recognised evidence of good practice and may be referenced by fire strategies, contracts, insurers and enforcing authorities.
Require relevant fire precautions and maintenance; for blocks of flats, scope includes structure, external walls and flat entrance doors.
For residential buildings over 11 metres, require quarterly checks of common-part fire doors and best endeavours to check flat entrance doors at intervals not exceeding 12 months.
Current code of practice for specification, installation and maintenance of timber-based fire door assemblies.
The fire strategy, risk assessment, original test evidence, product instructions and certification can all affect the appropriate inspection and repair decision.
Testing and maintenance
There is no single professional-inspection interval for every fire door. Frequency should reflect legal triggers, risk, use, condition and the fire risk assessment, with defects dealt with promptly.
Responsible staff can look for wedging, obstruction, damage and failure to self-close during normal premises checks.
The 2022 Regulations require quarterly checks of common-part fire doors and best endeavours to check flat entrance doors at intervals not exceeding 12 months.
Set a risk-based inspection schedule considering traffic, vulnerability to damage, importance to the fire strategy and previous findings.
Inspect promptly after impact, forced entry, access-control installation, glazing or ironmongery work, or changes to adjacent construction.
Common findings
A failed test, damaged component or undocumented change should be assessed and dealt with according to its effect on life safety—not simply left until the next scheduled visit.
A closer that cannot shut the door fully into its frame prevents the door from performing when needed.
Gaps, warping or frame movement can allow early passage of smoke and fire.
Intumescent strips and smoke seals may be missing, painted over, cut, loose or incompatible.
Locks, letterplates, viewers, ventilation grilles, cables or access-control devices can compromise tested construction.
From enquiry to records
Share the postcode, building use, size, current provision and the work or problem you need addressed.
A provider may ask for documents, photographs, asset numbers, access details or a preliminary survey.
Check what is included, exclusions, standards, certification, timescale, remedial rates and reporting.
Coordinate access, occupants, isolations and any temporary precautions needed while work is underway.
Retain reports, certificates, asset schedules, test results and evidence that identified defects were resolved.
Planning a quotation
Useful quotations are based on the actual scope and condition, not a single headline price.
Door count, types, ratings, locations and whether flat access must be coordinated.
Visual survey, evidence review, gap measurements, reporting detail and any intrusive work.
Height, multiple cores, occupied flats, security and out-of-hours arrangements.
Reliable door schedules, drawings and certificates can improve inspection efficiency and conclusions.
Free planning tool
Enter the door count, survey depth, premises type and access arrangements to produce a transparent indicative range.
Choosing a provider
Ask who will survey, design, install, commission, inspect or maintain the provision and what evidence supports their competence for that role. Check relevant experience, insurance, third-party certification where applicable, reporting, exclusions and how defects will be prioritised.
Related precautions
Changes to one measure can affect detection, escape, compartmentation, lighting, signs, equipment and the emergency plan. Keep the fire risk assessment and records aligned.
Frequently asked questions
Frequency is risk-based except where a specific legal requirement applies. In residential buildings over 11 metres, common-part fire doors require quarterly checks and best endeavours must be used to check flat entrance doors at intervals not exceeding 12 months.
A suitable inspection considers the complete doorset: leaf, frame, gaps, seals, hinges, closer, latch, glazing, ironmongery, signage, operation, damage and available evidence. The agreed scope should explain any limitations.
Some defects can be repaired using compatible, evidence-based methods by competent people. Other damage or unsupported alterations may require component or doorset replacement. A generic repair is not automatically suitable.
Yes, for buildings containing two or more sets of domestic premises, the Fire Safety Act clarified that the Fire Safety Order applies to flat entrance doors, as well as the structure, external walls and common parts.
No. Product evidence is valuable, but installation, compatibility, condition, alteration and ongoing operation also determine whether the doorset can perform properly.
Service-specific enquiry
Tell us about the premises and the work required. Your enquiry can be reviewed and passed to a suitable provider serving London or Surrey.
Sources and scope
This page provides general information for premises in England. Requirements depend on the fire risk assessment, building, people at risk and work scope. It is not a design, inspection, legal opinion or substitute for competent site-specific advice.