Fire Safety Order 2005
Requires a suitable and sufficient assessment, full recording, appropriate precautions, maintenance and cooperation between responsible persons.
Freeholders, managing agents and resident-led companies
Understand the assessment scope, height-based duties, evacuation strategy and records required for a block of flats, then request a tailored quote.
Key points
Property-specific guidance
Fire safety in a block of flats depends on the building’s construction, compartmentation, common escape routes, flat entrance doors, external walls, smoke control and management. A generic residential checklist cannot confirm whether those features support the intended evacuation strategy.
The assessment should reflect whether the building is purpose-built or converted, its height and storeys, layout, resident profile, alterations, ancillary uses and the evidence available. The inside of individual domestic flats is generally outside the Fire Safety Order, but the structure, external walls, common parts and doors between flats and common parts are within scope.
Legal responsibility
The responsible person may be the freeholder, housing provider, landlord, resident management company, right-to-manage company or managing agent, depending on control and legal obligations. There may be several responsible persons who must cooperate and coordinate.
Read the main fire risk assessment guideLegal framework
The Fire Safety Order is the core life-safety regime in England. Other laws and sector requirements can overlap, so the assessment and action plan should not be managed in isolation.
Requires a suitable and sufficient assessment, full recording, appropriate precautions, maintenance and cooperation between responsible persons.
Clarifies that the Order covers structure, external walls and flat entrance doors in buildings containing two or more domestic premises.
Add duties for all multi-occupied residential buildings and further requirements at over 11 metres and for high-rise buildings.
Creates a separate building-safety regime for higher-risk buildings; accountable and responsible persons need coordinated information and action.
Assessment scope
The final scope should reflect the actual building and any limitations. A site visit and a prioritised written report are fundamental for a professional assessment.
Confirm whether stay put, simultaneous, phased or another strategy is intended and whether the building can support it.
Consider fire-resisting walls, floors, service penetrations, risers, roof voids and evidence of uncontrolled alterations.
Inspect common doors and flat entrance doors proportionately, including self-closing, condition, seals, gaps and modifications.
Record relevant wall construction, balconies and attachments and identify when specialist appraisal or further information is needed.
Review alarm arrangements where present, smoke control, emergency lighting, signs, firefighting equipment, lifts and fire-service facilities.
Check resident information, contractors, testing, defects, access, housekeeping, storage, mobility needs and action tracking.
Property-specific hazards
These examples are prompts, not a complete checklist. The assessment must identify all significant hazards and how they could affect people in and around the premises.
Unsealed services, refurbishment and legacy construction can let fire and smoke move beyond the flat of origin.
Missing or failed closers, damage and unsupported alterations can expose the common escape route.
Items in corridors, meter cupboards, bin areas and under stairs may start or spread fire and obstruct escape.
Materials, cavities, attachments and balcony storage can affect external fire spread and may need specialist appraisal.
People at risk
The assessment must consider everyone lawfully on or near the premises, including people who may be unable to recognise danger, respond quickly or use the standard escape route without help.
Mobility, sensory or cognitive needs can affect information, evacuation and emergency planning.
Residents may be asleep and unaware of a fire elsewhere in the building.
People unfamiliar with the layout or strategy need clear information and controlled work.
Plans, wayfinding, lifts, smoke control and reliable building information can materially affect operational response.
Emergency planning
A written plan is only useful if it matches the building, occupants, available staff and fire precautions and can be carried out under foreseeable conditions.
What to expect
Confirm the areas in scope, responsible persons, occupancy, plans, previous reports and relevant fire-safety records.
Walk the premises and examine hazards, people at risk, escape, fire protection and management arrangements.
Judge whether precautions are suitable for the actual use, occupants, construction and emergency strategy.
Document findings in full and provide a clear, risk-prioritised action plan with responsible owners.
Keep the assessment current and revisit it when change, an incident or new information may affect its validity.
Evidence and management
Good records help an assessor understand the premises, allow defects to be tracked and demonstrate that significant findings have been acted on.
Keeping it current
There is no single fixed review interval suitable for every premises. Set a proportionate programme and review sooner whenever there is reason to think the assessment may no longer be valid.
Quote planning
A useful quote reflects assessor time, competence, site access and reporting complexity. A low headline price is not meaningful without a clear scope.
Storeys, cores, flats, common areas, basements and ancillary buildings.
Conversions, external walls, smoke control, mixed uses and incomplete records.
Extent of sampling or inspection and the common systems included.
Flat access, resident coordination, plans, previous reports and certification.
Choosing an assessor
BAFE SP205 provides third-party certification for organisations delivering life-safety fire risk assessments. The National Fire Risk Assessors Register (NFRAR), administered by the Institute of Fire Safety Managers, records individually assessed fire risk assessors and their competency level.
Use both as complementary evidence: verify the organisation’s current BAFE SP205 status where applicable and the individual’s current NFRAR registration and assessed level. Also check direct experience with block of flats premises, insurance, report scope, site visit, exclusions and how follow-up questions are handled.
Related fire-safety services
The FRA should define outcomes and priorities. Any design, installation, inspection or maintenance work must then be scoped and completed competently.
Fire doors and protected routes
Sleeping risk, vulnerable occupants, repeated use and flat-access arrangements can make door condition and records especially important in this premises type.
Local coverage
Explore local assessor information and quotation guidance, or use the form below to request a property-specific quote.
Frequently asked questions
Yes. The responsible person must ensure a suitable and sufficient assessment covers the areas and elements within the Fire Safety Order, including common parts, structure, external walls and flat entrance doors.
The Fire Safety Order generally does not apply inside individual domestic premises. However, flat entrance doors, structure and external walls are in scope, and access to flats may be needed for door checks or to understand relevant building features.
There is no universal legal annual interval. It must be reviewed regularly and when there is reason to suspect it is no longer valid, including after significant changes, incidents or new construction information. The review programme should reflect risk and building complexity.
No. The FRA considers fire risk across the premises. An FRAEW is a specialist appraisal of external-wall fire risk, commonly using PAS 9980. An EWS1 is a valuation-related form and is not a fire risk assessment or general safety certificate.
Responsible persons must undertake quarterly checks of common-part fire doors and use best endeavours to check flat entrance doors at intervals not exceeding 12 months, while keeping the required records.
Property-specific enquiry
Provide the essential building and occupancy details. Your enquiry can be reviewed and passed to an assessor serving London or Surrey.
Sources and limitations
This page provides general information for England. It is not legal advice, a building-specific assessment or a guarantee of compliance. Fire Safety Services is independent and is not affiliated with BAFE, NFRAR, IFSM, the Government or fire and rescue services.
Other property guides