Survey and design
Assess escape routes, open areas, risk points, existing lighting, duration and the applicable fire strategy.
Escape lighting and system testing
Understand where emergency lighting may be needed, how it should be tested and maintained, and request a tailored quote for London or Surrey premises.
Service overview
Emergency lighting operates when the normal lighting supply fails. Its life-safety functions can include illuminating escape routes, open areas, changes of level, fire alarm call points, firefighting equipment and high-risk task areas so that people can respond and move safely.
The required coverage and duration depend on the premises, evacuation arrangements, occupancy, building layout and fire risk assessment. A few self-contained luminaires may suit a straightforward building; larger sites can require central power systems, monitoring and detailed test arrangements.
Start with the fire risk assessment. It should identify the precautions needed for the actual premises and explain how this service fits the emergency plan and wider fire-safety arrangements. Read the fire risk assessment guide.
Scope of work
A quotation should state exactly which parts of the work are included and who is responsible for design decisions, access, certification and any remedial work.
Assess escape routes, open areas, risk points, existing lighting, duration and the applicable fire strategy.
Provide suitable luminaires, exit signs, supplies, controls, test facilities and identification.
Verify operation and duration, record test results and provide drawings, certificates and a logbook.
Simulate a short supply failure, confirm fittings operate and record faults without unnecessarily exhausting batteries.
Demonstrate that the system operates for its rated duration and allow time for batteries to recharge afterwards.
Replace failed batteries or fittings, correct coverage gaps and respond to layout or use changes.
Building-specific requirements
The examples below are a guide, not a specification. The appropriate solution must follow the premises risk, use, relevant standards and any existing fire strategy.
Helps people identify and use corridors, stairs, exits, changes of direction and final exits.
Reduces panic and supports movement towards an escape route in larger open spaces.
Allows hazardous processes to be made safe or stopped before occupants leave.
Supports continuation of normal activities where loss of normal lighting would cause disruption; this is distinct from minimum escape provision.
Law and recognised guidance
British Standards are codes of practice rather than legislation in themselves. They can nevertheless provide recognised evidence of good practice and may be referenced by fire strategies, contracts, insurers and enforcing authorities.
Requires emergency routes and exits needing illumination to have emergency lighting of adequate intensity if normal lighting fails.
Current code of practice for emergency lighting of premises, including emergency escape, local-area and standby lighting.
Related standards address lighting performance and emergency escape-lighting systems, including testing and records.
The assessment, evacuation plan, fire strategy and building regulations help determine necessary coverage and duration.
Testing and maintenance
A planned regime should suit the system and current standards. Tests must be recorded, faults corrected and full-duration tests timed so batteries can recharge before the building is exposed to avoidable risk.
Check indicators and central equipment where fitted and note damaged, obscured or visibly defective luminaires.
Simulate failure of the normal supply long enough to confirm that each emergency light and internally illuminated exit sign operates.
Test the system for its rated duration and inspect the result. Arrange the timing and temporary precautions around recharge and occupancy.
Reassess coverage after changes to partitions, furniture layouts, escape routes, hazards, use or occupancy.
Common findings
A failed test, damaged component or undocumented change should be assessed and dealt with according to its effect on life safety—not simply left until the next scheduled visit.
A fitting may appear normal on mains power but fail or fade quickly during a supply interruption.
Partitions, displays or altered routes can create dark points and obscure exit signs.
Unrecorded tests and unresolved faults weaken assurance that the system is dependable.
Unsafe isolation methods, inaccessible keys or unclear circuit identification make regular testing difficult.
From enquiry to records
Share the postcode, building use, size, current provision and the work or problem you need addressed.
A provider may ask for documents, photographs, asset numbers, access details or a preliminary survey.
Check what is included, exclusions, standards, certification, timescale, remedial rates and reporting.
Coordinate access, occupants, isolations and any temporary precautions needed while work is underway.
Retain reports, certificates, asset schedules, test results and evidence that identified defects were resolved.
Planning a quotation
Useful quotations are based on the actual scope and condition, not a single headline price.
Self-contained or central systems, maintained or non-maintained luminaires and specialist units.
Stairs, high ceilings, external routes, multiple buildings and out-of-hours work.
Short functional checks, full-duration testing, reporting and asset schedules.
Battery failures, obsolete fittings, missing drawings and circuit or coverage problems.
Choosing a provider
Ask who will survey, design, install, commission, inspect or maintain the provision and what evidence supports their competence for that role. Check relevant experience, insurance, third-party certification where applicable, reporting, exclusions and how defects will be prioritised.
BAFE SP203-4 provides third-party certification modules for emergency-lighting design, installation, commissioning and maintenance. Verify the provider holds the module relevant to your work.
Check the relevant BAFE schemeRelated precautions
Changes to one measure can affect detection, escape, compartmentation, lighting, signs, equipment and the emergency plan. Keep the fire risk assessment and records aligned.
Frequently asked questions
It is required where necessary to allow safe escape if normal lighting fails. Some very simple premises may rely on acceptable borrowed lighting or another justified arrangement, but the decision must come from the fire risk assessment and applicable guidance.
A common standards-based regime combines routine visual checks, a monthly functional test and an annual full-rated-duration test. The system design, manufacturer information and risk assessment should set the actual arrangements.
Rated duration depends on the premises and evacuation or reoccupation needs. Three hours is common, but it should not be assumed without checking the design, fire strategy and applicable standard.
A short monthly test confirms initial operation but may not reveal a battery that cannot sustain the rated duration. That is one reason a properly managed annual duration test is also important.
Short tests often can be managed safely, but a full-duration test depletes batteries and needs planning around occupancy, daylight, recharge time and temporary precautions.
Service-specific enquiry
Tell us about the premises and the work required. Your enquiry can be reviewed and passed to a suitable provider serving London or Surrey.
Sources and scope
This page provides general information for premises in England. Requirements depend on the fire risk assessment, building, people at risk and work scope. It is not a design, inspection, legal opinion or substitute for competent site-specific advice.