Ordinary FRA
Considers relevant fire risks and precautions for the premises, including available external-wall information where within scope.
British standard methodology
PAS 9980 provides a risk-based methodology for a fire risk appraisal of external walls in existing multistorey, multi-occupied residential buildings. The FRAEW informs the building’s FRA; it is not an EWS1 form or a whole-building assessment.
External-wall evidence route
Start with the purpose of the evidence. A valuation form, specialist risk appraisal and whole-building fire risk assessment are connected, but one does not automatically replace another.
Considers relevant fire risks and precautions for the premises, including available external-wall information where within scope.
A specialist appraisal of external-wall fire-spread risk that can inform the whole-building FRA and risk management.
A valuation and lending process for a specific building; it is not a fire-safety certificate or general legal compliance form.
Design, approvals, installation, inspection, commissioning and completion records used to demonstrate what changed.
Scope note: The necessary route depends on the building, the known concern and who needs the evidence. Obtain appropriately competent advice before commissioning intrusive or specialist work.
Purpose and scope
A fire risk appraisal of external walls assesses the risk to occupants from fire spreading over or within the external-wall construction and decides whether remediation or other mitigating measures are considered necessary in the building’s particular circumstances.
PAS 9980 applies where risk is known or suspected to arise from the external-wall build-up, such as potentially combustible materials. It is intended principally for existing multistorey, multi-occupied residential buildings and can inform assessments of comparable accommodation with a similar evacuation strategy.
Proportionality
The Fire Safety Act requires the external wall to be considered in the FRA for relevant residential buildings, but that does not mean every wall needs a full PAS 9980 appraisal. The initial assessor should consider available information, observed construction and the building’s risk profile.
A specialist appraisal becomes more likely when construction is uncertain, potentially combustible materials or cavities are present, defects are suspected, previous evidence conflicts, or the consequences of external fire spread cannot be judged reliably within the ordinary FRA.
Appraisal process
The specialist builds an evidence base from documents, site observations and, where justified, further investigation. The appraisal considers fire performance, routes of fire spread, façade configuration, ignition scenarios, fire barriers, balconies, windows and the ability of other measures to reduce consequences.
PAS 9980 is risk-based. It is not simply a material-combustibility test and does not assume that every combustible component produces the same overall building risk. Conclusions must be explained and limitations stated.
Identify the elevations, wall systems and questions the appraisal must answer.
Use reliable drawings, records, photographs, surveys and product information.
Confirm accessible features and decide whether targeted opening-up is justified.
Consider likelihood of external fire spread and consequences for occupants.
Explain whether mitigation, remediation or further work is proportionate.
Provide the outcome to the responsible person for the wider FRA and action plan.
Common confusion
FRAEW describes the fire risk appraisal produced using the PAS 9980 methodology. EWS1 is a separate valuation process administered by RICS for lenders and valuers. BSI expressly states that PAS 9980 is not intended as an alternative to EWS1.
A building may encounter both processes, but they have different purposes, clients and outputs. The scope and reliance of each instruction should be agreed in writing so that a valuation request is not mistaken for fulfilment of the responsible person’s fire-safety duties.
| Document or process | Primary purpose |
|---|---|
| Ordinary FRA | Assess relevant persons and general fire precautions under the Fire Safety Order. |
| PAS 9980 FRAEW | Appraise occupant risk from external-wall fire spread and inform the FRA. |
| EWS1 | Provide information for a valuation process administered by RICS. |
| Product or façade survey | Answer specified technical questions; it may supply evidence but is not automatically a FRAEW. |
Commissioning
BSI says PAS 9980 is particularly intended for competent fire engineers and other competent building professionals. Competence must cover the construction under review, fire dynamics, façade behaviour, risk appraisal and the ability to recognise when other disciplines are needed.
Commissioning should define access, evidence, investigation allowances, reporting, professional indemnity insurance, reliance and how the output will be incorporated into the FRA and building-safety records.
Current remediation evidence
Use the June 2026 MHCLG tracker for programme totals, regional comparisons and permanent local-authority profiles. The data is aggregate management information and does not establish the position of an individual building.
See the whole framework
Return to the regulations hub to compare legislation, height thresholds and voluntary standards before deciding what applies to your building.
Frequently asked questions
No. It is a voluntary code of practice. The law requires relevant external-wall risks to be considered; PAS 9980 provides a recognised methodology where a specialist FRAEW is appropriate.
No. The need should be determined proportionately from the building, available evidence and suspected risk. Every relevant FRA must consider the external wall, but not every case needs a full FRAEW.
No. A FRAEW is a fire risk appraisal of external walls. EWS1 is a separate valuation process administered by RICS.
Only if they have the specialist competence appropriate to the external-wall construction and risk. Many ordinary FRA commissions will need referral to a suitably competent fire engineer or building professional.
No. Its conclusions should inform and be integrated into the wider fire risk assessment and action plan.