Checking programme guide

Fire door inspection frequency and regime

A good regime combines quick operational checks, competent periodic inspection and prompt defect management. One interval and one checklist cannot suit every door or building.

Reviewed: 26 August 2026Guidance: EnglandInspection enquiries: London and Surrey

Direct answer

What is the difference between a check and an inspection?

A routine check can confirm that a door is present, unobstructed, visibly sound and closes. A competent detailed inspection can investigate identity, evidence, components, gaps, glazing, interfaces and the significance of defects. An intrusive investigation may be needed only where justified and agreed.

Layered assurance

What is the difference between a check and an inspection?

A routine check can confirm that a door is present, unobstructed, visibly sound and closes. A competent detailed inspection can investigate identity, evidence, components, gaps, glazing, interfaces and the significance of defects. An intrusive investigation may be needed only where justified and agreed.

Government guidance for Regulation 10 describes simple checks; it does not state that those checks replace the wider fire risk assessment or every technical inspection.

LevelTypical personPurpose
User or caretaker observationInformed staff, residents or site teamSpot obstruction, damage and obvious closing failure
Recorded routine checkTrained in-house person or contractorConsistent functional and visual checks
Detailed doorset inspectionCompetent fire-door inspectorAssess components, evidence, condition and priorities
Specialist investigationRelevant manufacturer, engineer or specialistResolve concealed construction or uncertain performance

Set the interval

How often should fire doors be inspected?

For specified residential buildings over 11 metres, communal doors require checks at least every three months and flat entrance doors require best-endeavours checks at least every 12 months. Elsewhere, use risk, traffic, misuse, environment, manufacturer information and the fire strategy to set intervals.

A busy corridor door, school door, hotel bedroom door or frequently damaged service door may need more observation than a locked low-use cupboard. A recent inspection does not justify waiting when a defect is reported.

  • Door role and people protected
  • Usage, damage and repair history
  • Environmental and pressure conditions
  • Legal, manufacturer and insurer requirements
  • Consequences if the door fails

Close the loop

What should an inspection programme record?

Give each door a stable identifier and record location, intended performance, check type, date, inspector, findings, photographs, limitations, priority and action. Link repair evidence and verification to the same record.

Use trend information to identify repeated closer failures, resident access problems, contractor quality issues and doors that need a design solution rather than another minor repair.

Apply the guidance

Move from a reference question to a doorset decision

Identify the door’s role and evidence, record its actual condition, then choose the level of inspection or remedial support the building requires.

01Use the free checklist02Inspection scope guide03Estimate inspection cost04Find an inspector

Frequently asked questions

Fire door inspection frequency and regime FAQs

These answers provide general guidance for England. The correct conclusion depends on the door, building, design evidence and people at risk.

Is a yearly fire door inspection always enough?

No. Some doors need more frequent checks because of legal duties, use, risk or damage. Others may have a different competent-inspection interval supported by the risk assessment.

Can maintenance staff complete fire door checks?

They can complete checks within their training and competence. Uncertain performance, detailed evidence and specialist repair require appropriate expertise.

Do quarterly checks apply to every workplace?

The specific quarterly communal-door duty under the 2022 Regulations applies to defined multi-occupied residential buildings over 11 metres. Workplaces still have maintenance duties and need a risk-based regime.

Professional support

Find a fire door inspector in London or Surrey

Describe the premises, approximate number of doors and the concern or deadline. A relevant provider can review the likely inspection scope and contact you about a quotation.

  • No obligation to proceed
  • Telephone number required for useful follow-up
  • Your enquiry may be shared with a relevant provider

Submitting this form does not confirm an appointment, fixed price or compliance outcome.

Sources and limitations

Guidance reviewed 26 August 2026

This page is general information for England. It is not legal advice, a fire-risk assessment, product specification, certification decision or inspection of an installed doorset. Standards can be amended; confirm the edition and transition applicable to the work.