Controlled door release

Fire door hold-open devices

A fire door may be held open only by a suitable arrangement that releases it when required and allows it to close fully. A wedge or uncontrolled hook removes that safety function.

Reviewed: 26 August 2026Guidance: EnglandInspection enquiries: London and Surrey

Direct answer

What types of hold-open arrangement are available?

Hard-wired electromagnetic retainers release when their supply or alarm signal changes. Integrated free-swing or hold-open closers allow easier movement but retain a controlled closing function. Some devices listen for an alarm sound and have defined environmental and alarm-signal limitations.

Permitted solutions

What types of hold-open arrangement are available?

Hard-wired electromagnetic retainers release when their supply or alarm signal changes. Integrated free-swing or hold-open closers allow easier movement but retain a controlled closing function. Some devices listen for an alarm sound and have defined environmental and alarm-signal limitations.

Selection must fit the fire strategy, alarm system, door, users, risk and doorset evidence.

ArrangementNormal useCritical check
Electromagnetic retainerDoor held at a fixed open positionReleases on alarm and power loss as designed
Free-swing closerDoor moves freely in ordinary useEngages and closes on the required signal
Acoustic releaseResponds to a recognised alarm patternSuitable sound level, environment, testing and fail-safe behaviour
Uncontrolled wedge or hookPrevents closure with no automatic releaseNot an acceptable hold-open safety system

System coordination

What must the device connect to?

The design may rely on the fire alarm, local detection, power supplies, cause-and-effect and time controls. Smoke detectors may be needed on both sides or in defined positions depending on the arrangement and standard.

A device that releases but leaves the door obstructed, unlatched or unable to overcome floor resistance has not achieved the objective. Test the entire sequence.

  • Alarm or detection signal initiates release
  • Power failure produces the intended safe state
  • Door path is clear
  • Closer shuts and latches the leaf
  • Reset procedure does not mask a fault

Routine control

How should hold-open devices be managed?

Include devices in routine fire-door and alarm testing arrangements. Record failed release, depleted batteries, altered sounders, obstruction and changes to the space. Close doors at appropriate times where the management plan requires it.

Do not fit a device purely to solve complaints about opening force without reviewing accessibility, alarm compatibility and the door’s fire role.

Apply the guidance

Move from a reference question to a doorset decision

Identify the door’s role and evidence, record its actual condition, then choose the level of inspection or remedial support the building requires.

01Use the free checklist02Inspection scope guide03Estimate inspection cost04Find an inspector

Frequently asked questions

Fire door hold-open devices FAQs

These answers provide general guidance for England. The correct conclusion depends on the door, building, design evidence and people at risk.

Are magnetic fire door holders legal?

They can be suitable when correctly designed, connected, installed, tested and maintained for the building and door. The generic product type is not approval for every location.

Can I use a door wedge during working hours?

A wedge provides no automatic release and defeats the self-closing function. Use a properly specified controlled arrangement if holding the door open is necessary.

What is a free-swing fire door closer?

It allows the door to move with little resistance in normal use but engages the closing function on a defined alarm or fail-safe signal.

Professional support

Find a fire door inspector in London or Surrey

Describe the premises, approximate number of doors and the concern or deadline. A relevant provider can review the likely inspection scope and contact you about a quotation.

  • No obligation to proceed
  • Telephone number required for useful follow-up
  • Your enquiry may be shared with a relevant provider

Submitting this form does not confirm an appointment, fixed price or compliance outcome.

Sources and limitations

Guidance reviewed 26 August 2026

This page is general information for England. It is not legal advice, a fire-risk assessment, product specification, certification decision or inspection of an installed doorset. Standards can be amended; confirm the edition and transition applicable to the work.