Perimeter protection guide

Intumescent and smoke seals

Intumescent seals and smoke seals perform different functions. The correct type, size, location and configuration come from the doorset evidence and building design.

Reviewed: 26 August 2026Guidance: EnglandInspection enquiries: London and Surrey

Direct answer

What is the difference between fire and smoke seals?

Intumescent material expands when exposed to elevated temperature and helps protect gaps and hardware details during a fire-resistance test. A smoke seal—often a brush, blade or other tested arrangement—limits ambient-temperature smoke leakage.

Two functions

What is the difference between fire and smoke seals?

Intumescent material expands when exposed to elevated temperature and helps protect gaps and hardware details during a fire-resistance test. A smoke seal—often a brush, blade or other tested arrangement—limits ambient-temperature smoke leakage.

A product can combine both functions, but the presence of a brush alone does not prove the correct fire or smoke performance.

SealPrimary roleTypical evidence question
IntumescentResponds to heat during fire exposureType, dimensions, location and continuity
Smoke sealLimits ambient smoke leakageLeakage classification and threshold arrangement
Combined sealProvides both functions within its field of applicationCompatibility with leaf, frame and hardware

Condition checks

What defects should be recorded?

Look for missing lengths, damage, loose seals, paint build-up that prevents operation, incorrect joints, interruption around hardware and an apparently mixed specification. Confirm that the seal is located in the leaf or frame as required by the evidence.

Do not scrape, relocate or add seals simply to match another door. Older doors may have been designed under different standards; investigate the door and its role before prescribing change.

  • Continuous and securely retained
  • Not crushed, painted over or damaged
  • Correct position and apparent size
  • Compatible at hinges, latch and closer points
  • Threshold and meeting-stile condition considered

Repair decisions

Can seals be replaced?

Replacement can be appropriate where the original specification is known and the new product is compatible. Where it is not known, a competent specialist should establish an evidence-based repair or recommend proportionate replacement.

Record the product, size, location, installer and date. Retest the door’s closing and latching after work because new seals can change resistance.

Apply the guidance

Move from a reference question to a doorset decision

Identify the door’s role and evidence, record its actual condition, then choose the level of inspection or remedial support the building requires.

01Use the free checklist02Inspection scope guide03Estimate inspection cost04Find an inspector

Frequently asked questions

Intumescent and smoke seals FAQs

These answers provide general guidance for England. The correct conclusion depends on the door, building, design evidence and people at risk.

Do all fire doors need smoke seals?

No. Smoke-control requirements depend on the door location, building design and relevant guidance. Where required, the complete leakage path—including thresholds—matters.

Can fire door seals be painted?

Paint can damage or inhibit some products. Follow the manufacturer’s information; heavy paint build-up, damage or loss of flexibility should be assessed.

Can seals be added to an old fire door?

Only after establishing the door’s intended performance and a compatible detail. Government guidance cautions against assuming absence of modern strips alone makes an older residential door unsuitable.

Professional support

Find a fire door inspector in London or Surrey

Describe the premises, approximate number of doors and the concern or deadline. A relevant provider can review the likely inspection scope and contact you about a quotation.

  • No obligation to proceed
  • Telephone number required for useful follow-up
  • Your enquiry may be shared with a relevant provider

Submitting this form does not confirm an appointment, fixed price or compliance outcome.

Sources and limitations

Guidance reviewed 26 August 2026

This page is general information for England. It is not legal advice, a fire-risk assessment, product specification, certification decision or inspection of an installed doorset. Standards can be amended; confirm the edition and transition applicable to the work.